Thickener TH001 Replacement

Address:
765 N 10500 W, Ogden, UT, 84404
Project Type:
Conditional Use Permits
Sub Type:
Conditional Use Permits
Created By:
Created On:
10/9/2014
Project Status:
Submitted
Status Date:
10/17/2014
File Number:
CUP 2014-27
Project Manager

Application

The 240 foot diameter Thickener TH001 rake and drive mechanism requires replacement. They will also be updating switch gears, vista switches, transformers, pumps, adding a 900 square foot control building, a 40,000 gallon mix tank, water flow pumps, over flow tank and pumps, as well as a new 3 foot access bridge on a existing tank. I met with Mr. Lloy this morning and the tank diameter is actually 18 feet and not 240 feet as note else where.  they have an existing Site Polution Prevention Plann I asked for them to send us a copy to put with the file for record puposes.  i still recomend the project for approval.  I believe rochelle is acking as Project manager for the construction permit.  Blane Frandsen


Property Address
765 N 10500 W
Ogden, UT, 84404

Property Owner

--

Representative

--

False
0
1
,

Parcel Number
100320004 - County Map

Building Description Square Feet Valuation

Contractor Type Name Contact Address


Documents

List of project documents. Review documents can be found under the Review tab.

Document Name Date Uploaded
Options
Building renderings
Easement documents
Engineered Plans
Geologic hazards study
Geotechnical report
Landscaping Plan
Narrative
Notice of decision
Other
Original signed_admin_aproval_letter.pdf 10/17/2014
Review CPR-_GSL_Minerals_Thickener_765_N_10500_W_Weber_County.pdf 10/16/2014
Original CUP_2014-27_Drawings.pdf 10/9/2014
Original CUP_2014-27_Thickener_TH001_Replacement_Application.pdf 10/9/2014
Permits issued
Planning staff report
Signage Plan
Site Plan
Time Extension
Water and Wastewater Plan
Uncategorized Documents

Comments

Have a question? Leave a comment, your comment will be emailed to all project followers.

Reviews

To access review documents, click on the individual review and the corresponding review documents will be listed under the review.

Weber county Building Inspections

Approved

Weber County Building Inspection Stan Berniche 12/9/2014
Administrative Approval

Approved

Jim Gentry 10/17/2014
Weber Fire District Review

Approved

N/A N/A 10/16/2014
Project CUP

Approved

Blane W Frandsen 10/16/2014

Followers

All followers will be notified of new documents, comments, and reviews to the project.

Name Date Added
Options
Stan Berniche 1/1/0001
Blane W Frandsen 1/1/0001
Jim Gentry 1/1/0001
Brian Lloyd 1/1/0001

Payments

List of all invoices tied to project.